Hose storage

Storage conditions of rubber hose products When we use

阅读更多

Storage conditions of rubber hose products

When we use a kind of product, we also need to master its related storage knowledge. In many cases, it is due to our improper storage of its products, which causes damage to it. The same is true for the storage of rubber tube products. Many problems are Special attention needs to be paid to:

  1. For the storage of rubber tube products, it is recommended to store them at 10 degrees Celsius to 25 degrees Celsius. Note: Do not store the rubber tube at a temperature above 40 degrees Celsius or below 0 degrees Celsius.

Special care should be taken when moving rubber hoses below -15°C. The rubber tube should not be stored near the heat source, and the relative humidity should not exceed 65%.

  1. Its storage should not be exposed to light. The storage room for storing rubber tubes should be kept dark, especially avoid direct sunlight or strong artificial light on the rubber tubes. If storage rooms have windows or any openings covered by glass, they should be screened.

How to Determine the Length of a Pressure Test Hose

The length of the pressure measuring hose is very important. We often do not do this work well when determining the length of the pressure measuring hose, so that the pressure measuring hose in the working state is often caused by improper length determination. or something like that. For example, if the pressure measuring hose used in the pipeline system is too long, it will generate greater fluid resistance and so on. Therefore, determining the length of the pressure measuring hose is a very important task. Below, several methods for determining the length of the pressure measuring hose in different usage occasions are introduced.

  1. The length of the gooseneck used as a compensator depends on the size of the diameter. In the pipeline system, if the compensation amount of one compensator is not enough, two or three can be used. If it is impossible to install a large number of compensators due to the limitation of space conditions, a duplex structure can be selected.
  2. The length of the pump inlet and pump outlet pipe used for vibration and noise elimination depends on the size of its diameter, that is, if the diameter is less than or equal to 100 mm, L is the length of the compensator or the flexible section of the ultra-high pressure hose; The diameter of the compensator or ultra-high pressure hose.
  3. The length of the pressure measuring hose with angular displacement depends on its actual bending radius and displacement angle. That is, the length of the pressure measuring hose with lateral displacement depends on its actual bending radius and lateral displacement. The tangent section refers to the intermediate transition section between two pipes with the same radius and bent in different directions when the pressure measuring hose is displaced laterally.

Proudly powered by WordPress | Theme: SpicePress by SpiceThemes